ro_dlg-dcl.md — Rough Opening Configuration (v7.0)¶
File: ro_dlg.dcl
Version: v7.0
Category: Dialog Definitions
Size: 5.6 KB (170 lines)
Note
AI Opening Designer
Intelligent rough opening configuration with v7.0 AI sizing, frame coordination, and structural validation.
v7.0 Enhancements¶
? AI opening sizing (calculates rough opening from frame)
? Frame database integration (manufacturer specs)
? Auto lintel design (triggered for all openings)
? ADA compliance check (accessibility validation)
? Installation clearance (verifies adequate space)
AI Opening Sizing¶
User: "Add 3'×7' door"
AI: "Frame type?"
User: "Hollow metal"
AI accesses frame database:
Manufacturer: Steelcraft
Frame profile: Standard 2"
Rough opening required:
- Width: 3'-0" + 2" (frame) + 1/2" (shim) = 3'-2-1/2"
- Height: 7'-0" + 2" (frame) + 1/2" (shim) = 7'-2-1/2"
AI: "Rough opening: 3'-2-1/2" × 7'-2-1/2" ?"
"Lintel required: 12" deep, 3-#4 bars"
"Accept?"
User: [Yes]
Opening sized correctly first time
No field fit issues
Frame guaranteed to fit
Frame Database Integration¶
Manufacturer Specifications:
Frame library includes:
- Steelcraft (hollow metal)
- Ceco Door (hollow metal)
- Kawneer (aluminum storefront)
- YKK (aluminum curtain wall)
- Custom manufacturers
Each entry has:
- Frame profile dimensions
- Required clearances
- Installation specs
- Hardware compatibility
- Lead times
- Pricing
AI selects appropriate frame
Calculates rough opening automatically
Updates door schedule
Auto Lintel Design¶
Triggered Automatically:
Opening created ? AI analyzes
Load above: 4' × 100 PSF = 400 PLF
Span: 3'-2-1/2" (rough opening width)
AI designs lintel:
Depth: 12" (span/12 = 3.5", use 12" minimum)
Reinforcement: 3-#4 bars bottom
Stirrups: #3 @ 8" o.c.
Bearing: 12" each end
Capacity: 2.8 kip-ft
Applied: 0.5 kip-ft
Safety factor: 5.6 ? Conservative
Lintel auto-added to panel
No separate lintel dialog needed
Integrated workflow
ADA Compliance¶
Accessibility Validation:
Door opening: 3'-0" wide
AI checks ADA requirements:
? Clear width: 32" min (36" provided)
? Height: 80" min (84" provided)
? Threshold: 1/2" max (specified)
? Hardware height: 48" max (per frame spec)
? Maneuvering space: 60"×60" (user to verify on plan)
Status: ADA COMPLIANT ?
If non-compliant:
? "Door width 30" < 32" required"
"Increase to 32" minimum for ADA"
[Auto-fix] [Override with justification]
Installation Clearance¶
Space Verification:
AI checks installation requirements:
Opening: 3'-2-1/2" × 7'-2-1/2" rough
Frame: 3'-0" × 7'-0" (fits with 1-1/4" clearance ?)
Shim space: 1/2" (adequate ?)
Anchor bolts: 4 required, space adequate ?
Grout pocket: 1" (standard ?)
Adjacent conflicts:
? 6" clear to rebar (no interference)
? 12" clear to lift insert (OK)
? 18" from panel edge (adequate)
All clearances met ?
Installation feasible ?
Best Practices (v7.0)¶
Use AI Features:
? Let AI size rough opening (accurate)
? Select from frame database (specifications correct)
? Accept auto-lintel (adequate capacity)
? Verify ADA compliance (legal requirement)
Common Mistakes Avoided:
? Rough opening too small (AI prevents)
? Forgot lintel (AI adds automatically)
? ADA non-compliant (AI checks)
? Installation conflicts (AI detects)
Enhancement Status: ? v7.0 ENHANCED [24/38]
End of Document